How is the installation with PU joint treatment?

|   Interior

To ensure a good connection with AQUAPANEL® Joint Adhesive (PU), clean the edges, for example, using a wet brush (e.g. Pinkel Brush). Apply AQUAPANEL® Joint Adhesive (PU) before placing the next board. Leave the adhesive to harden, after which the excess AQUAPANEL® Joint Adhesive (PU) is scraped off (usually the next day). The joints between the walls, ceiling and floor require permanent elastic sealing in dry areas. Expansion joints should not exceed a maximum distance of 7.5 m.

Please consider that according to the new REACH regulation that will come into effect on August 8th, 2023, you must have completed a training for safe use of diisocyanates before using any product containing Diisocyanantes commercially or industrially! For more information please click here!