After leaving a spacing of 5mm when fixing the boards, fill all joints with AQUAPANEL® Joint Filler & Skim Coating – white, and then embed AQUAPANEL® Tape (10 cm) centered over all joints. Apply a thin layer of AQUAPANEL® Joint Filler & Skim Coating – white to cover the tape. Expansion joints should be at a minimum of 15 m intervals.